Online statistics and data analysis support for USA, UK and international clients. No exams, no impersonation, no fabricated data.
15 complete interactive investigation pathways

AP Physics 2 Labs & Investigations

Use experiments to connect a physical model to measurable evidence. Every investigation follows the same student workflow: research question, experiment plan, manual or automatic data collection, apparatus operation, accepted trials, model-appropriate graphing, uncertainty, results, discussion and conclusion. Automatic datasets are clearly labeled and never replace the manual experiment.

15full interactive labs7 units · experimental evidence

What should an AP Physics 2 laboratory investigation include?

A useful physics lab identifies a testable model, independent and dependent variables, controls, a repeatable measurement procedure, an appropriate graph or transformation, uncertainty, and a conclusion that uses data as evidence. The graph must be chosen from the physics model—not merely because every dataset is expected to have a straight-line fit.

15 labsall fully interactive
Manual trialsstudent-controlled measurement
Auto datasetclearly separated quick mode
Full reportresults → discussion → conclusion
Use these as supervised investigation tools, not as a claim of automatic course-lab credit.

AP Physics 2 courses require a minimum of 25% of instructional time in hands-on laboratory investigations. Current course requirements allow virtual labs or simulations when circumstances prevent onsite access, provided the investigation is supervised by a science educator and includes student data collection, analysis, and a maintained lab record. These interactive investigations are designed to support that evidence cycle; a teacher determines how they fit a course laboratory program.

Lab navigator

Jump to any investigation

Each lab is tied to its relevant Physics 2 topics and uses a graph or analysis chosen from that model.

Investigation workflow

Use the same evidence cycle in every lab

The apparatus changes, but the reasoning sequence stays consistent so the experiment can be written up as a defensible physics investigation.

1Question & modelState what relationship is being tested and the assumptions that make the model valid.
2MeasureOperate the apparatus, control competing variables and accept only defensible readings.
3RecordKeep the raw measurements visible in a trial table; do not replace the measurements with a calculated answer.
4AnalyzeChoose the graph or transformation from the physics model. Fit only when the model actually predicts a fit.
5ConcludeReport uncertainty, discuss limitations and connect the measured evidence to the research question.
LAB 1 · THERMODYNAMICS · HANDS-ON APPARATUS

Determine the Pressure–Temperature Relationship of a Fixed-Volume Gas

Research question: For a fixed amount of gas in a rigid sealed vessel, how does absolute pressure depend on absolute temperature?

0 / 5 recorded trials Drag the thermostat handle to set Trial 1
Lab 1 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelP = (nR/V)T
Independent variableBath temperature T (K)
Control variablesGas amount n and rigid volume V
MeasureStable absolute pressure
GraphPressure P versus temperature T
FindSlope ≈ nR/V
Choose how to collect data Manual apparatus trials
1Drag the orange thermostat handle on the apparatus to choose a bath temperature.
2Press Start bath circulation. The gas temperature must approach the bath temperature before measurement.
3When the equilibrium light turns green, press Arm pressure sensor.
4Press Capture stable pressure. Inspect the instrument reading and accept or discard the run.
5Press Record accepted trial, drag the thermostat to a new temperature, and repeat until five trials are stored.

Physical procedure

  1. Seal a fixed amount of gas in a rigid vessel and connect an absolute-pressure sensor.
  2. Immerse the vessel in a controllable temperature bath and allow the gas to reach thermal equilibrium before each reading.
  3. Record temperature in kelvins and absolute pressure only after both readings are stable.
  4. Use at least five well-spaced temperatures while keeping the gas amount and vessel volume fixed.
  5. Plot P against T. Compare the measured slope with nR/V and inspect whether the intercept is physically plausible within uncertainty.
Safety

In a physical classroom version, use a rated rigid vessel and remain within the pressure and temperature limits of the apparatus. The virtual apparatus practices the same measurement sequence without pressurizing real equipment.

Model and evidence

For a fixed amount of dilute gas in a rigid container, the ideal-gas model gives

P = (nR/V)T

A P-versus-T graph should therefore be approximately linear. Its slope is nR/V. A substantial nonzero intercept, curvature or drifting slope should trigger a check of sensor zero, thermal equilibrium, fixed volume and model limits.

Do not use Celsius for the proportionality test

The proportional model requires absolute temperature in kelvins. A Celsius graph can look linear but its intercept has a different meaning and cannot represent P ∝ T through the origin.

Direct manipulation mode Drag the orange thermostat handle on the bath scale. Touch, mouse and keyboard arrows are supported.
RIGID SEALED GAS VESSEL n = 0.015 mol · V = 350 mL · fixed for all five trials ABS PRESSURE — kPa SENSOR NOT ARMED BATH THERMOSTAT — DRAG TO SET TEMPERATURE 275 K 300 325 350 375 390 K DRAG Bath target: 300 K Gas: 300.0 K NOT EQUILIBRATED
Drag the thermostat handle to choose the first bath temperature. Nothing is recorded until you operate the apparatus and accept the reading.

Operate the experiment

Gas amount0.015 mol
Rigid volume350 mL
Bath target300 K
Gas temperature300.0 K
Pressure sensor— kPa
EquilibriumNot tested

Hold n = 0.015 mol and V = 350 mL fixed. Only bath temperature should change between accepted trials. Use absolute pressure and kelvin.

Prediction: increasing absolute temperature should increase absolute pressure when n and V are fixed.
Recorded trials
TrialBath / gas T (K)Absolute P (kPa)n (mol)V (mL)Source
No readings recorded. Manipulate the apparatus and perform Trial 1.

The graph begins with your recorded scatter only. A best-fit line is added only when requested. Final analysis unlocks after five accepted trials.

LAB 2 · THERMODYNAMICS · HANDS-ON CALORIMETRY

Determine the Specific Heat of an Unknown Metal by Calorimetry

Research question: Can an energy-balance experiment identify the specific heat of an unknown metal from measured masses and temperatures?

0 / 5 recorded trials Prepare the apparatus for Trial 1
Lab 2 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelQmetal + Qwater + Qcal = 0
UnknownSpecific heat cmetal
Control variablesSame metal + same calorimeter
MeasureMasses and initial/final temperatures
RepeatFive accepted mixing trials
ReportMean corrected c ± trial SD
Choose how to collect dataManual apparatus trials
1Choose the unknown metal and water amount, then press Prepare measured sample to read the balance and initial water temperature.
2Press Heat metal in bath. Wait until the metal reaches the hot-water bath temperature before transfer.
3Press Transfer metal + stir. The hot metal must be moved quickly into the calorimeter and mixed until thermal equilibrium.
4Press Capture equilibrium temperature. Inspect the probe reading and discard it if you want to repeat that measurement.
5Press Record accepted trial, adjust the water amount or starting temperature, and repeat until five trials are stored.

Physical procedure

  1. Dry and weigh the metal sample. Measure the water mass in the insulated calorimeter.
  2. Measure the water's initial temperature. Heat the metal in a hot-water bath long enough for the metal to approach the bath temperature.
  3. Transfer the hot metal rapidly into the calorimeter, cover it, stir gently, and watch the temperature probe.
  4. Record a stable final temperature. The final temperature must lie between the initial metal and water temperatures.
  5. Repeat the full mixing procedure with the same unknown metal. Calculate one specific-heat estimate per trial, then summarize the five-trial mean and scatter.
Safety

Hot metal, hot water and steam can burn skin. Use tongs, eye protection and a stable insulated calorimeter. The virtual apparatus below is for practicing the measurement logic.

Energy accounting

If the calorimeter starts at the same temperature as the water, use

mmcm(Tf−Tm,i) + mwcw(Tf−Tw,i) + Ccal(Tf−Tw,i) = 0

with cw = 4186 J·kg⁻¹·K⁻¹ and the virtual calorimeter heat capacity fixed at 18 J/K.

Why two answers are shown

The table reports a simple two-object estimate that ignores the cup and a calorimeter-corrected estimate. In a hot-metal/cool-water experiment, ignoring a cup that absorbs energy usually biases the metal's calculated specific heat low.

Manual calorimetry apparatusOperate the balance, hot bath, calorimeter and temperature probe in sequence. Nothing enters the data table until you accept the reading.
HOT-WATER BATH METAL Metal temperature22.0 °C Bath target95.0 °C INSULATED CALORIMETER WATER METAL PROBE Water / mixture temperature22.0 °C APPARATUS STATUS READY TO PREPARE TRIAL 1 Tf —
Choose the unknown sample and water conditions, then press 1. Prepare measured sample.

Operate the experiment

Measured metal mass— g
Measured water mass— g
Metal temperature22.0 °C
Water temperature22.0 °C
Probe reading— °C
Current stageNot prepared

Keep the same unknown metal and calorimeter for one five-trial data set. The hot bath is fixed at 95.0 °C and Ccal = 18 J/K.

Prediction: after mixing, Tmetal,i > Tf > Twater,i. If the final temperature falls outside that interval, reject the run.
Recorded trials
Trialmm (g)mw (g)Tm,i (°C)Tw,i (°C)Tf (°C)c simplec correctedSource
No readings recorded. Operate the calorimetry apparatus and perform Trial 1.

Trial number is a repeated-measurement label, not a physical independent variable. Do not force a regression. Compare the corrected trial estimates, their mean and spread, and the bias from neglecting the calorimeter.

LAB 3 · THERMODYNAMICS · HANDS-ON PISTON

Compare Work Along Two P–V Paths with the Same Endpoints

Research question: If a gas starts and ends at the same thermodynamic states, does the work done by the gas depend on the process path?

0 / 5 paired checkpoints Prepare the piston apparatus
Lab 3 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelWby = ∫P dV
ComparePath A vs Path B
ControlSame initial and final states
MeasurePressure P and volume V
Manual datasetFive paired checkpoints
GraphPressure P versus volume V
Choose how to collect dataManual piston trials
1Choose common endpoint values, then press Prepare and zero sensors. Endpoint controls lock when the apparatus is prepared for the five-checkpoint series.
2Move the process checkpoint slider to the required mark: 0%, 25%, 50%, 75%, then 100%.
3Press Capture Path A state. Read the piston volume and absolute pressure before accepting the state.
4Press Capture Path B state at the same checkpoint. The endpoints remain identical but the intermediate state can differ.
5Press Record paired checkpoint. Repeat for all five marks, then plot both paths and compare the signed P–V areas.

Physical procedure

  1. Use a low-friction piston or gas syringe connected to an absolute pressure sensor and a calibrated volume scale.
  2. Choose one initial state (P1, V1) and one final state (P2, V2) for both processes.
  3. For Path A, change pressure and volume gradually together. For Path B, change pressure first at nearly fixed volume, then change volume at nearly constant final pressure.
  4. At each of five ordered checkpoints, measure both paths without reordering the data. The order is part of the process.
  5. Plot P versus V and estimate work with the trapezoid rule. Use 1 kPa·L = 1 J.
Sign convention

This lab reports work done by the gas. Expansion gives positive Wby; compression gives negative Wby. Work on the gas has the opposite sign.

Prediction before measuring

Both paths have the same endpoints, so the state change is the same. The area under the P–V curve can still differ because work is a path/process quantity.

First-law connection

Using ΔU = Q − Wby, the same ΔU with different Wby requires different heat transfer Q.

Uncertainty

Pressure resolution, volume-scale reading, piston friction and failure to pause at a quasi-static state all affect the area estimate. Five well-spaced ordered checkpoints are more useful than many rushed readings.

Manual piston + pressure sensorSet the required checkpoint, capture Path A, then Path B. Nothing enters the table until both readings are accepted and recorded.
LOW-FRICTION GAS PISTON GAS 0.7 L 1.3 1.9 2.5 3.1 L ABS PRESSURE — kPa NO PATH CAPTURED CURRENT APPARATUS STATE READY TO PREPARE V — L PROCESS CHECKPOINT 0% 25% 50% 75% 100%
Set common endpoints, then press 1. Prepare and zero sensors.

Operate the experiment

Next required checkpoint0%
Current checkpoint0%
Path A captureNot captured
Path B captureNot captured
Endpoint lockUnlocked
Paired rows0 / 5

Use the same P1, V1, P2, V2 for both paths. The five ordered checkpoints are 0%, 25%, 50%, 75%, 100%.

Prediction: Path A should have a larger positive P–V area than Path B for the default expansion.
Recorded paired checkpoints
CheckpointPath A V (L)Path A P (kPa)Path B V (L)Path B P (kPa)Source
No paired checkpoints recorded. Prepare the apparatus and perform the 0% checkpoint.

Use the five checkpoints in recorded order. The vertical constant-volume portion of Path B contributes approximately zero work because ΔV ≈ 0. The graph is P versus V, so signed area has units kPa·L = J.

LAB 4 · ELECTROSTATICS · HANDS-ON FIELD MAPPING

Map Electric Potential and Infer the Electric Field

Research question: Do measured potential values between fixed parallel electrodes support the model of an approximately uniform electric field in the central region?

0 / 5 recorded points Prepare the field tray
Lab 4 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelEx ≈ −ΔV/Δx
Independent variableProbe position x
Dependent variableElectric potential V
ControlsElectrode spacing + applied ΔV
Manual datasetFive accepted probe positions
AnalysisV vs x slope → field
Choose how to collect dataManual apparatus measurements
1Choose electrode spacing and applied voltage, then press Prepare electrodes + zero meter. These controls lock for one five-point run.
2Drag the purple voltage probe along the center line until it reaches the highlighted target position.
3Press Arm high-resistance voltmeter after the probe is at the required position.
4Press Capture stable potential. Inspect the reading and discard/repeat it if necessary.
5Press Record accepted point, then move to the next target. Repeat until five points are stored.

Physical procedure

  1. Connect two parallel electrodes to a DC source and keep the electrode spacing fixed.
  2. Use a high-resistance voltmeter so the probe does not substantially disturb the electric field.
  3. Measure potential at five well-spaced positions along the central line between the electrodes.
  4. Keep the applied potential difference and electrode geometry unchanged during the run.
  5. Plot V against x. The slope estimates dV/dx, so the electric-field component is the negative slope.
Safety & apparatus care

Use only a low-voltage classroom DC source. Do not short the electrodes with the probe or a conductor. The virtual apparatus below practices the same measurement logic.

What the model predicts

For ideal parallel electrodes, the central field is approximately uniform. If potential rises toward +x, then the x-component of the field is negative:

Ex ≈ −dV/dx ≈ −ΔV/d

The field points from higher electric potential toward lower electric potential. Equipotential lines are perpendicular to the field direction.

Model limit

Finite electrodes produce edge/fringing effects. This experiment deliberately samples the central region and does not claim a perfectly uniform field everywhere.

Parallel-electrode field trayDrag the probe only when Manual lab is active.
E direction PROBE VOLTMETER — V 0 V +12 V APPARATUS NOT PREPARED
Choose the electrode settings, then prepare and zero the apparatus.

Student controls

Current probe position10.0% of gap
Next required target10%
Voltmeter statusNot armed
Captured potentialNot captured
Manual rule: record the five target positions in order: 10%, 30%, 50%, 70%, 90% of the electrode gap.
Prediction: because V increases toward +x, the fitted V-vs-x slope should be positive and Ex should be negative.
0 / 5
Pointx (cm)x/dMeasured V (V)Source
No field-map points recorded. Prepare the apparatus and perform the 10% target.

Do not infer the electric field from a single point. Use the slope of the complete V-versus-x dataset and include its sign.

LAB 5 · CAPACITORS · HANDS-ON APPARATUS

Test the Parallel-Plate Capacitance Model

Research question: How does capacitance depend on plate overlap area, plate separation, or dielectric constant when the other two quantities are held fixed?

0 / 5 recorded trials Choose one experiment design
Lab 5 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelC = κε0A/d
Design AVary A → graph C vs A
Design dVary d → graph C vs 1/d
Design κVary κ → graph C vs κ
Control ruleChange one variable only
Manual datasetFive accepted meter readings
Choose how to collect dataManual capacitance measurements
1Select one design, set the two control variables, then press Prepare capacitor + zero meter. The controls lock for the run.
2Move the highlighted independent-variable slider to the next required target shown by the instrument panel.
3Press Arm capacitance meter only after the setting matches the target.
4Press Capture stable capacitance. Inspect the reading and discard/repeat it if necessary.
5Press Record accepted trial, then move to the next target. Repeat until five measurements are stored.

Physical procedure

  1. Connect a parallel-plate capacitor to a capacitance meter and zero the meter before collecting data.
  2. Choose exactly one independent variable: overlap area A, separation d, or dielectric constant κ.
  3. Keep the other two quantities fixed for all five measurements.
  4. For the separation experiment, transform the horizontal axis to 1/d because the model predicts C ∝ 1/d.
  5. Use slope agreement, R², measurement uncertainty, and a nonzero intercept to judge the model rather than declaring agreement from one point.

What the slope should mean

  • Vary A: slope = κε0/d, expressed here in pF per cm².
  • Vary d: plot C against 1/d; slope = κε0A, in pF per m⁻¹.
  • Vary κ: slope = ε0A/d, in pF per unit κ.
Model limit

The ideal parallel-plate expression assumes plates are parallel and edge/fringing effects are small. Parasitic capacitance and plate misalignment can produce a nonzero intercept or weaker agreement.

Parallel-plate capacitor bench Change only the highlighted independent variable after preparation. The meter must be armed before each capture.
PARALLEL-PLATE CAPACITOR VARY AREA A · HOLD d AND κ FIXED d = 2.0 mm A = 50 cm² κ = 1.00 CAPACITANCE METER — pF NOT ARMED NEXT REQUIRED SETTING A = 50 cm² prepare the apparatus Capacitance preview: 22.14 pF
Choose one experiment design, set the controls, and prepare the capacitor bench.

Operate the experiment

Next targetA = 50 cm²
Current settingA = 50 cm²
MeterNot captured
Control lockUnlocked
DesignVary A
Recorded trials0 / 5

The two control variables and meter precision must remain fixed during a five-trial series. Only the chosen independent variable may change after preparation.

Design A: vary overlap area while holding separation and dielectric constant fixed. Graph C versus A.
Recorded capacitance trials
TrialDesignA (cm²)d (mm)κGraph xC (pF)Source
No capacitance measurements recorded. Prepare the apparatus and perform Trial 1.

Use the graph required by the chosen model. For Design d, plot C against 1/d rather than against d itself.

LAB 6 · ELECTRIC ENERGY · HANDS-ON APPARATUS

Test Electric Potential Energy → Kinetic Energy

Research question: When a positive test charge is released from rest through a known electric potential drop, does its measured kinetic-energy gain equal the decrease in electric potential energy, qΔVdrop?

0 / 5 recorded trials Prepare the apparatus for Trial 1
Lab 6 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelΔK = qΔVdrop
Independent variablePotential drop ΔV
Control variablesCharge q and particle mass m
MeasureFinal speed v
GraphKmeasured vs qΔV
EvidenceSlope ≈ 1, intercept ≈ 0
Choose how to collect dataManual apparatus trials
1Choose q, m and photogate precision, then press Prepare track + zero gate. These controls lock for the run.
2Move the potential-drop control to the next required ΔV target shown on the apparatus.
3Press Place charge at start, then Release charge from rest through the electric field.
4Press Arm photogate and then Capture final speed. Inspect the measured speed and kinetic energy.
5Press Record accepted trial, or discard the reading and repeat. Continue until five trials are stored.

Physical procedure

  1. Use a positively charged test particle released from rest at the higher-potential side of the apparatus.
  2. Keep the charge and mass fixed while changing only the electric potential drop.
  3. Measure the final speed with the photogate after the particle crosses the acceleration region.
  4. Calculate K = ½mv² from the measured speed and calculate qΔV from the electrical settings.
  5. Plot measured K against qΔV. Energy conservation predicts a slope of 1 and an intercept near zero.

What counts as evidence?

  • A straight K-versus-qΔV trend across all five accepted measurements.
  • A best-fit slope close to 1 rather than agreement at only one voltage.
  • An intercept small compared with the measured energy range.
  • Acknowledgment that photogate precision, stray forces and nonuniform/fringing fields can shift the measured energy.
Sign convention

This lab uses ΔVdrop = Vstart − Vend > 0 for a positive charge. The electric potential energy decreases by qΔVdrop, while kinetic energy increases by the same amount in the ideal model.

Electric acceleration track Set the required voltage, place the charge at the start, release it, then capture the final speed at the photogate.
ELECTRIC ACCELERATION REGION HIGHER V LOWER V +q PHOTO GATE NEXT REQUIRED POTENTIAL DROP 20 V Ready to prepare apparatus
Prepare and zero the apparatus before the first release.

Student controls

Required ΔV20 V
Measured speed— m/s
Measured K— mJ
qΔV0.080 mJ
Predict first: if q and m remain fixed, increasing ΔV should increase both the final speed and final kinetic energy.
TrialSourceq (µC)m (g)ΔV (V)v (m/s)K (mJ)qΔV (mJ)
No electric-energy trials recorded.

Use all five accepted measurements. The central test is whether measured K is proportional to qΔV with slope near 1.

LAB 7 · ELECTRIC CIRCUITS · HANDS-ON APPARATUS

Ohmic Resistor vs Filament Lamp I–V Investigation

Research question: When the applied potential difference is changed, does current remain proportional to voltage for an ohmic resistor, and how does the response change for a self-heating filament lamp?

0 / 5 recorded trialsPrepare the circuit for Trial 1
Lab 7 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelOhmic: I = V/R
Independent variableApplied voltage V
Control variablesOne element, wiring, meter precision
MeasureVoltage V and current I
Primary graphI vs V
EvidenceConstant V/I or systematic change
Choose how to collect dataManual apparatus trials
1Choose the test element, nominal low-voltage resistance and meter precision, then press Build circuit + zero meters. These controls lock for the run.
2Move the source-voltage control to the next required voltage target shown on the apparatus.
3Press Close switch, then Wait for stable reading. For the lamp, this represents waiting for the filament temperature to settle.
4Press Arm meters and then Capture V–I reading. Inspect the voltmeter and ammeter values.
5Press Record accepted trial, or discard the capture and repeat. Continue until five trials are stored.

Physical procedure

  1. Connect the ammeter in series with the test element and the voltmeter in parallel across it.
  2. Keep one element and the same wiring for the complete five-point voltage series.
  3. At each target voltage, close the switch and wait for the reading to stabilize before capturing V and I.
  4. Calculate the operating resistance from R = V/I and power from P = VI for every accepted measurement.
  5. For the resistor, test whether I versus V is linear. For the lamp, use the changing V/I values and curved I–V trend as evidence instead of forcing a straight-line model.

What counts as evidence?

  • Ohmic resistor: nearly constant V/I and a high-quality straight-line I–V trend whose slope is about 1/R.
  • Filament lamp: V/I rises as voltage and filament temperature increase, while current grows less than proportionally.
  • All five points must come from one fixed element and one fixed nominal setup.
  • Meter resolution, lead/contact resistance, source internal resistance and thermal lag must be considered when interpreting small deviations.
Do not misuse a linear fit

A poor straight-line fit for the lamp is not automatically experimental error. The nonlinearity is the physical behavior being investigated.

DC I–V test circuitAmmeter in series · voltmeter across the element · switch opened between trials
CURRENT–VOLTAGE TEST CIRCUIT DC SOURCE2.0 V SWITCH A OHMIC RESISTORI = — mA V NEXT REQUIRED SOURCE VOLTAGE2.0 VReady to build circuit
Build the circuit and zero both meters before taking the first measurement.

Student controls

Required V2.0 V
Voltmeter— V
Ammeter— mA
V/I resistance— Ω
Ohmic prediction: at fixed R, doubling V should double I and V/I should remain approximately constant.
TrialSourceElementV (V)I (mA)V/I (Ω)P (W)
No I–V measurements recorded.

Use all five accepted measurements. A resistor may justify a best-fit line; a filament lamp should be interpreted through curvature and changing V/I resistance.

LAB 8 · ELECTRIC CIRCUITS · HANDS-ON APPARATUS

Kirchhoff Junction & Loop Verification

Research question: When a fixed resistor network is driven at several source voltages, do the measured branch currents satisfy charge conservation at the junction and do the measured potential changes sum to zero around each loop?

0 / 5 recorded trialsPrepare the circuit for Trial 1
Lab 8 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelΣI at junction = 0
Independent variableBattery voltage
Control variablesR₁, R₂, R₃, meter precision
MeasureI₁, I₂, I₃ and V₁, V₂, V₃
Primary graphI₁ vs I₂ + I₃
Loop evidenceVbat − V₁ − Vbranch ≈ 0
Choose how to collect dataManual apparatus trials
1Choose R₁, R₂, R₃ and meter precision, then press Build network + zero meters. The resistor network locks for the run.
2Set the source to the next required battery voltage shown on the apparatus.
3Press Close switch, then Wait for stable network before taking any readings.
4Press Arm meters and then Capture network readings. Inspect all three currents and three resistor voltage drops.
5Press Record accepted trial, or discard and repeat. Continue until all five source-voltage trials are stored.

Physical procedure

  1. Wire R₁ in series with a junction that splits into parallel branches R₂ and R₃.
  2. Measure I₁ before the junction and I₂, I₃ in the two branches. Measure V₁ across R₁ and V₂, V₃ across the parallel resistors.
  3. Keep the same resistor network for all five source voltages.
  4. At each source setting, test the junction rule with I₁ − I₂ − I₃ and the two loop rules with Vbat − V₁ − V₂ and Vbat − V₁ − V₃.
  5. Use the complete five-point series to decide whether the conservation residuals are small compared with measurement uncertainty.

What counts as evidence?

  • The I₁ versus I₂+I₃ graph should have slope near 1 and intercept near 0.
  • Both signed loop residuals should scatter around 0 V rather than grow systematically with source voltage.
  • Do not add absolute voltage drops before deciding a loop traversal direction; Kirchhoff's loop rule uses signed potential changes.
  • Small nonzero residuals are expected from meter loading, resistor tolerance, contact resistance and source internal resistance.
Keep the network fixed

Changing R₁, R₂ or R₃ midway creates a different circuit. Reset the lab before collecting a new five-point series.

Series–parallel Kirchhoff networkThree ammeters · three voltmeter drops · one fixed resistor network
KIRCHHOFF NETWORK DC SOURCE3.0 Vmeasured Vbat SWITCH A₁ R₁100 ΩJUNCTION A₂R₂150 Ω A₃R₃220 Ω CURRENT METERSI₁ — · I₂ — · I₃ — RESISTOR VOLTAGE DROPSV₁ — · V₂ — · V₃ — NEXT REQUIRED SOURCE VOLTAGE3.0 VReady to build network
Build the network and zero the current and voltage meters before taking the first measurement.

Student controls

Required Vbat3.0 V
I₁— mA
I₂ + I₃— mA
Loop residuals— V
Prediction: in steady state, I₁ should equal I₂+I₃ and the signed potential changes around either closed loop should sum to zero.
TrialSourceVbat (V)I₁ (mA)I₂ (mA)I₃ (mA)Junction residual (%)Loop 2 (V)Loop 3 (V)
No Kirchhoff measurements recorded.

Use the current-conservation graph and the signed loop residuals together. A line fit is appropriate for I₁ versus I₂+I₃; the loop residuals should instead remain near zero.

LAB 9 · ELECTRIC CIRCUITS · HANDS-ON APPARATUS

RC Time-Constant Landmark Experiment

Research question: If capacitance and the measurement method are held fixed while resistance changes, does the measured 63% charging or 37% discharging landmark time scale with the circuit time constant RC?

0 / 5 recorded trialsPrepare the RC circuit for Trial 1
Lab 9 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelτ = ReqCeq
Independent variableResistance R
Control variablesC, source voltage, transient type
Measure63% / 37% landmark time
Primary graphMeasured tlandmark vs RC
Course boundaryLandmark timing, not exponential fitting
Choose how to collect dataManual apparatus trials
1Choose charging or discharging, capacitance, source voltage and sensor precision. Press Build RC circuit + zero timer. These controls lock for the run.
2Set the resistance to the next required R value shown on the apparatus, then press Prepare initial state so the capacitor starts fully discharged or fully charged as required.
3Press Arm voltage sensor + timer. Confirm the target landmark voltage: about 63% of the final voltage when charging or 37% of the initial voltage when discharging.
4Press Trigger transient, then Capture landmark time when the sensor detects the target voltage. Inspect the measured time before accepting it.
5Press Record accepted trial, or discard and repeat. Continue until all five resistance settings are stored, then plot and analyze the complete dataset.

Physical procedure

  1. Use one capacitor and one source voltage for the entire five-trial series.
  2. For a charging trial, begin with the capacitor discharged; for a discharging trial, begin with the capacitor charged to the source voltage.
  3. Change only the resistance between trials. Measure the time required to reach the appropriate landmark voltage.
  4. Calculate RC for each trial and compare it directly with the measured landmark time.
  5. Use the slope, intercept and scatter of the five-point graph to decide whether the data support τ = RC.

What counts as evidence?

  • At one time constant, a charging capacitor is at about 63% of its final charge/voltage.
  • At one time constant, a discharging capacitor is at about 37% of its initial charge/voltage.
  • A graph of measured landmark time versus calculated RC should have slope near 1 and intercept near 0.
  • Do not fit or require an exponential charging/discharging equation in this lab. Use the landmark and qualitative curve shape.
Control variables matter

Changing capacitance, source voltage, transient type or sensor method midway creates a different experiment. Reset before starting a new five-point series.

RC transient stationDC source · switch · resistor bank · capacitor · voltage sensor · timer
RC LANDMARK STATION DC SOURCE6.0 Vfixed for run TRANSIENT SWITCH R20 kΩ C47 µF CAPACITOR VOLTAGE SENSORVc —target — LANDMARK TIMER— s NEXT REQUIRED RESISTANCE20 kΩReady to build RC circuit
Build the circuit and zero the timer before taking the first landmark measurement.

Student controls

Required R20 kΩ
Calculated RC0.940 s
Landmark voltage3.78 V
Measured landmark time— s
Prediction: with C fixed, the 63% charging landmark should occur at t ≈ RC for every resistance setting.
TrialSourceTransientR (kΩ)C (µF)RC (s)Landmark V (V)Measured t (s)Difference (%)
No RC landmark measurements recorded.

Plot measured landmark time against calculated RC. The slope should be near 1. This lab intentionally does not require an exponential fit.

LAB 10 · MAGNETISM · HANDS-ON APPARATUS

Magnetic Force on a Current-Carrying Wire

Research question: When magnetic field strength and the other wire variables are controlled, does the measured force follow F = BIL sinθ as current, active wire length, or angle changes?

0 / 5 recorded trialsPrepare the force station for Trial 1
Lab 10 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modelF = BIL sinθ
Independent variableI, L, or sinθ
Control variablesB + remaining model factors
MeasureMagnetic force F
Primary graphF vs selected variable
EvidenceSlope compared with theory
Choose how to collect dataManual apparatus trials
1Choose whether to vary current, active wire length, or angle. Set the control variables and sensor precision, then press Assemble station + tare force sensor.
2Move the selected independent variable to the next required target shown on the apparatus, then press Set required variable.
3Press Energize field + wire. Keep the current direction and magnetic-field direction unchanged during the five-trial series.
4Press Wait for stable force, then Arm force sensor and Capture stable force. Inspect the reading before accepting it.
5Press Record accepted trial, or discard and repeat. Continue until all five targets are stored, then plot, fit and analyze the full dataset.

Physical procedure

  1. Place a straight wire segment in a uniform magnetic-field region and connect it to a controlled current source.
  2. Tare the force sensor before energizing the wire so the reading represents the magnetic force change.
  3. Change only the selected independent variable. Hold magnetic field and the remaining model factors fixed.
  4. For angle mode, record the actual angle and use sinθ as the graph variable.
  5. Compare the experimental slope with the factor predicted by F = BIL sinθ.

What counts as evidence?

  • Vary I: slope of F vs I should be BL sinθ.
  • Vary L: slope of F vs L should be BI sinθ.
  • Vary angle: slope of F vs sinθ should be BIL.
  • A small intercept and high R² strengthen the proportional model, but uncertainty and alignment still matter.
Control variables matter

Changing more than one model factor during the series makes the slope ambiguous. Sensor zero offset, field nonuniformity, wire heating and angle error are important limitations.

Magnetic-force stationhorseshoe magnet · straight wire · DC source · force sensor
MAGNETIC FORCE STATION NSUNIFORM FIELD REGION CURRENT FORCE FORCE SENSOR— mN NEXT REQUIRED TARGET0.8 A CURRENT STATEI 0.8 A · L 20 cm · θ 90° Ready to assemble and tare station
Assemble the station and tare the force sensor before taking the first measurement.

Student controls

Required target0.8 A
Graph x-value0.800 A
Theoretical force64.0 mN
Measured force— mN
Mode I: B, L and θ stay fixed. The slope of F vs I should equal BL sinθ.
TrialSourceModeB (T)I (A)L (m)θGraph xMeasured F (mN)Expected F (mN)Difference (%)
No magnetic-force measurements recorded.

Use the graph required by the selected one-variable design. For angle mode, plot force against sinθ, not θ itself.

LAB 11 · ELECTROMAGNETIC INDUCTION · HANDS-ON APPARATUS

Faraday–Lenz Flux-Change Experiment

Research question: At fixed coil geometry and field change, does the measured induced-emf magnitude follow |ε| = N A |ΔB| / Δt, and does reversing the flux-change direction reverse the measured polarity?

0 / 5 recorded trialsPrepare the induction station for Trial 1
Lab 11 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics model|ε| = N|ΔΦ|/Δt
Independent variableFlux-change time Δt
Control variablesN, A, |ΔB|, orientation
MeasureAverage induced emf + polarity
Primary graph|ε| vs N A |ΔB|/Δt
Direction evidenceLenz polarity reversal
Choose how to collect dataManual apparatus trials
1Choose flux direction, coil turns, area, field change and sensor precision. Press Assemble coil + zero voltmeter; controls then lock.
2Set the next required field-change time shown on the apparatus, then press Set required sweep time.
3Press Run magnetic-field sweep. The field changes through the coil while orientation stays fixed.
4After the sweep completes, arm the voltmeter and capture average emf. Inspect magnitude and polarity.
5Record the accepted reading or discard and repeat. Continue through all five times, then plot, fit and analyze both magnitude and Lenz polarity.

Physical procedure

  1. Keep the coil face perpendicular to the field so ΔΦ = AΔB.
  2. Keep N, A and |ΔB| fixed while changing only the sweep time.
  3. Record both the signed emf and its magnitude.
  4. Do not average away polarity: the sign is separate directional evidence.
  5. Compare the magnitude slope with the ideal value 1.

Uncertainty and limitations

Sensor response time, nonuniform field, coil-angle error, uncertainty in sweep duration, lead orientation and incomplete field change affect the result. Very fast sweeps can challenge the voltmeter response.

Induction stationcoil · controlled field source · timer · signed voltmeter
FARADAY INDUCTION STATIONCHANGING B THROUGH COILSIGNED VOLTMETER— VNEXT SWEEP TIME0.12 sSTATEREADYReady to assemble and zero station
Assemble the coil and zero the signed voltmeter before Trial 1.

Student controls

Required Δt0.12 s
Predicted |ε|— V
Captured emf— V
Polarity—
Keep N, A and |ΔB| fixed; only the sweep time changes.
#SourceΔt (s)N A |ΔB|/Δt (V)Measured ε (V)Polarity
No induction trials recorded.

Magnitude is fitted with absolute values; polarity is evaluated separately with Lenz’s law.

LAB 12 · GEOMETRIC OPTICS · HANDS-ON APPARATUS

Determine Refractive Index from Snell’s Law

Research question: For one transparent sample, does the ratio of measured sine values obey n₁ sinθ₁ = n₂ sinθ₂, and can the sample refractive index be recovered from the slope of sinθ₁ versus sinθ₂?

0 / 5 recorded trialsPrepare the ray table for Trial 1
Lab 12 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics modeln₁ sinθ₁ = n₂ sinθ₂
Independent variableIncident angle θ₁
Control variablesSample, interface, wavelength
MeasureRefracted angle θ₂
Primary graphsinθ₁ vs sinθ₂
Findn₂ = slope for air
Choose how to collect dataManual apparatus trials
1Choose one sample and protractor precision. Press Mount sample + zero normal; the sample locks for the series.
2Set the laser to the next required incident angle, measured from the normal.
3Press Turn on laser + trace refracted ray, then wait for the ray line to settle.
4Arm the protractor and capture refracted angle. Inspect the reading before accepting it.
5Record the accepted angle or discard and repeat. After five angles, plot the sine-transformed data and determine refractive index.

Physical procedure

  1. Measure both angles from the interface normal, not from the surface.
  2. Keep the same material and interface through all five trials.
  3. Use a wide incident-angle range without approaching grazing incidence.
  4. Transform each angle using sine before fitting.
  5. For air, the slope of sinθ₁ vs sinθ₂ estimates n₂.

Uncertainty and limitations

Normal-line zero error, finite beam width, protractor resolution, sample alignment and identifying the center of the refracted ray dominate uncertainty.

Ray tablelaser · normal line · transparent block · protractor
WATERPROTRACTOR READING—°NEXT θ₁15°Ready to mount sample and zero normal
Mount one sample and zero the protractor normal before Trial 1.

Student controls

Required θ₁15°
Ideal θ₂—°
Captured θ₂—°
Sample index1.33
Use one sample for the complete five-angle fit.
#SourceSampleθ₁θ₂sinθ₁sinθ₂
No ray measurements recorded.

Fit sinθ₁ on the vertical axis against sinθ₂ on the horizontal axis.

LAB 13 · GEOMETRIC OPTICS · HANDS-ON APPARATUS

Thin-Lens Focal Length from Screen Focusing

Research question: Can the focal length of one converging lens be recovered by manually focusing five real images and testing 1/dᵢ = −1/dₒ + 1/f?

0 / 5 focused trialsPrepare the optical bench for Trial 1
Lab 13 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Physics model1/f = 1/dₒ + 1/dᵢ
Independent variableObject distance dₒ
Student adjustmentScreen distance dᵢ
MeasureFocused dₒ and dᵢ
Primary graph1/dᵢ vs 1/dₒ
Findf = 1/intercept
Choose how to collect dataManual focusing trials
1Choose one lens and ruler precision. Press Mount lens + zero optical bench; the lens locks for the run.
2Press Set required object distance for the next trial.
3Move the screen slider yourself until the focus indicator reaches SHARP.
4Press Lock sharp focus, arm the rulers and capture the measured distances.
5Record or discard the reading. Repeat for five object positions, then transform the distances and fit the thin-lens model.

Physical procedure

  1. Measure dₒ and dᵢ from the lens principal-plane approximation used by the bench.
  2. Use only real images that can be sharply focused on the screen.
  3. Do not record a trial until the focus indicator is within tolerance.
  4. Keep the same lens throughout the series.
  5. Interpret slope, intercept and the focal length inferred from the intercept.

Uncertainty and limitations

Focus judgment, ruler zero, lens thickness, distance reference points and parallax affect the fit. A narrow object-distance range weakens the transformed fit.

Optical benchilluminated object · converging lens · movable screen · rulers
BLURREDFOCUS QUALITY0%NEXT OBJECT DISTANCE24 cmReady to mount lens and zero bench
Mount one lens and zero the optical bench before Trial 1.

Student controls

Required dₒ24 cm
Focus statusBLURRED
Captured dₒ— cm
Captured dᵢ— cm
Move the screen slider until the image is sharp before locking focus.
#SourceLensdₒ (cm)dᵢ (cm)1/dₒ1/dᵢ
No focused trials recorded.

For the thin-lens model, slope should be near −1 and intercept should be 1/f.

LAB 14 · WAVES & PHYSICAL OPTICS · HANDS-ON APPARATUS

Wave Evidence Laboratory

Research question: Can a manually tuned standing-wave station and a manually measured double-slit station recover the model slopes predicted by wave speed and interference geometry?

0 / 5 recorded trialsChoose one station and prepare Trial 1
Lab 14 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Station AStanding-wave resonance
Station BDouble-slit interference
Manual actionTune resonance / measure fringe spacing
5-trial graphf vs n or Δy vs 1/d
Control variablesStation-specific geometry
EvidenceMeasured slope vs theory
Choose how to collect dataManual apparatus trials
Experiment plan

Physical procedure

Complete the steps below in order before accepting a trial. Keep the selected station and its control variables unchanged except for the intended independent variable.

1Choose standing wave or double slit, set the station controls and press Prepare station + zero instrument.
2Set the next required harmonic or slit spacing with Set required target.
3Standing wave: tune the driver slider until resonance is sharp. Double slit: move the ruler slider until it spans adjacent bright fringes.
4Press Lock resonance / fringe measurement, then arm and capture the instrument reading.
5Record or discard. Repeat exactly five trials in one station, then use the correct transformed graph and slope interpretation.

Station A — standing wave

At fixed string length L, tension T and linear density μ, the resonance frequencies satisfy fₙ = n v/(2L) with v = √(T/μ). Graph fₙ vs n.

Station B — double slit

At small angles, Δy ≈ λL/d. Keep wavelength and screen distance fixed, vary slit spacing d, and graph Δy vs 1/d.

Wave stationstring driver · frequency counter · resonance detector
STANDING-WAVE RESONANCEINSTRUMENT READING—NEXT TARGETn = 1Ready to prepare wave station
Choose one station and prepare the apparatus before Trial 1.

Student controls

Required targetn = 1
Expected reading—
Tuning / alignmentNOT LOCKED
Captured reading—
Standing wave: keep L, T and μ fixed while varying harmonic number.
#SourceStationGraph xMeasured yControl summary
No wave trials recorded.

Analyze only one station at a time; each station has its own physically meaningful graph.

LAB 15 · MODERN PHYSICS · HANDS-ON APPARATUS

Modern Physics Evidence Laboratory

Research question: Can a manually operated photoelectric station recover the linear stopping-potential slope, and can a manually counted decay station recover a sample half-life from population data?

0 / 5 recorded trialsChoose one station and prepare Trial 1
Lab 15 evidence workspaceKeep the research question, raw trials, graph and uncertainty visible when writing the conclusion.
Lab navigator
Station APhotoelectric stopping potential
Station BRadioactive population decay
Manual actionNull photocurrent / count survivors
Photo graphVstop vs f
Decay graphln N vs t
Evidenceh/e slope or half-life
Choose how to collect dataManual apparatus trials
Experiment plan

Physical procedure

Complete the steps below in order before accepting a trial. Keep the selected station and its control variables unchanged except for the intended independent variable.

1Choose photoelectric or decay, set the station controls and press Prepare station + zero instrument.
2Set the next required frequency or elapsed time shown on the apparatus.
3Photoelectric: illuminate and adjust retarding voltage until photocurrent is nulled. Decay: advance the sample clock to the target time.
4Lock the null/count state, arm the meter/counter and capture the reading.
5Record or discard. After five trials, fit only the physically appropriate transformed data and report uncertainty.

Photoelectric station

For above-threshold light, eVstop = hf − φ. The slope of Vstop vs f is h/e. Below-threshold points are valid observations but do not belong in the linear stopping-potential fit.

Decay station

For a large population, N(t)=N₀e−λt. Plot ln N vs t; slope = −λ and t½ = ln2/λ. Counting fluctuations are expected statistical scatter.

Modern physics stationphotocathode · variable-frequency light · retarding supply
PHOTOCATHODECOLLECTORMEASURED VALUE—NEXT TARGET6×10¹⁴ HzReady to prepare modern-physics station
Choose one station and prepare the apparatus before Trial 1.

Student controls

Required target6×10¹⁴ Hz
Expected state—
Null / count statusNOT LOCKED
Captured value—
Photoelectric: keep one metal fixed and vary frequency.
#SourceStationTargetMeasured valueAnalysis value
No modern-physics trials recorded.

Use above-threshold photoelectric points only; use ln N for the decay fit.

Laboratory evidence belongs in written reasoning too

After each investigation, use the FRQ Self-Grader and check whether your procedure, graph, uncertainty and evidence would be clear to someone who did not watch you perform the experiment.